AC Single Phase Digital Voltage Amps Power Energy Kwh Watt Panel Meter 110V 100A

$ 7.38

Availability: 20 in stock
  • All returns accepted: ReturnsNotAccepted
  • Condition: New
  • MPN: Does Not Apply
  • Brand: Peacefair
  • Measured Parameter(s): AC 80-260V 0-100A
  • Country/Region of Manufacture: China

    Description

    AC Single Phase Digital Voltage Amps Power Energy Kwh Watt Panel Meter 110V 100A
    Function
    1. Electrical parameter measurement function (voltage, current, active power, energy)
    2. Overload alarm function (over power alarm threshold, backlight and power flashing to alarm).
    3. Power alarm threshold preset function (can set power alarm threshold).
    4. The reset function of energy key.
    5. Store data when power off.
    6. Large-screen LCD (display voltage, current, active power, energy at the same time)
    7. Backlight function.
    Parameter
    1.  Power: test range: 0~22kW
    Within 1kW, the display format is 0.0~999.9W;
    Within 1kW~10kW, the display format is 1000~9999W;
    10kW and above, the display format is 0.1~22.0kW.
    2.   Energy: test range: 0~9999kWh
    Within 10KWh, the display format is 0~9999Wh;
    10kWh and above, the display format is 10~9999kWh.
    3.    Voltage: test range: 80~260V
    Display format: 80~260V
    4.   Current: test range: 0~100A
    Display format: 0.00~99.99A
    5.   Operating frequency: 45-65Hz
    6.
    Precautions
    1. This module is suitable for indoor, please do not use outdoor.
    2. Applied load should not exceed the rated power.
    3. Wiring order can’t be wrong.
    4. It can't be used in some circuit such as inverter or silicon controlled.
    Note:
    - There are three types of power: active power (
    P
    represents / unit
    W
    ), reactive power (
    Q
    represents / unit
    Var
    ),
    apparent power (
    S
    represents / unit
    VA
    ).
    - And the power of our product is active power.
    - Active power is calculated as: P = U * I * cosφ, cosφ represents the power factor, for purely resistive loads (such as
    incandescent, heater, etc.) the power factor is generally close to 1, for inductive load and capacitive load, the power
    factor is between 0-1; so when you test the purely resistive load, the power(P) is substantially equal to or close to U * I;
    but when you test inductive or capacitive loads (such as refrigerators, washing machines, televisions, computers, etc.),
    P so please believe the value of our product.
    Package included:
    1 * digital AC meter
    1 * toroidal current transformer
    1 * manual